Objective: To examine yttrium-90 distribution 1 and 72 h following its injection into a knee joint in patients with rheumatoid arthritis (RA). Methods: In 14 RA patients we injected yttrium-90 into the affected knee joint using lateral approach. To assess the radioisotope distribution in the joint, the superimposed sequential SPECT and CT imaging was performed 1 and 72 h after the injection. We analyzed the percentage of radioisotope distribution in three predefined compartments of the knee joint (lower, upper medial, upper lateral). Results: After 1 and 72 h, the mean percentage distributions were, respectively, 7.14 and 23.07 % in lower; 21.42 and 15.38 % in upper medial, and 71.42 and 61.53 % in upper lateral compartment. The percentage of isotope deposition did not change significantly with time in any of the compartments (all p > 0.26). The deposition of isotope, both at 1 and 72 h, was significantly greater in upper lateral compartment, where the injection was performed, than in all other compartments (all p < 0.05). Conclusions: Using the SPECT/CT hybrid method, we proved that the majority of isotope is located at the compartment adjacent to the injection. Two injections targeting different compartments might improve the clinical efficacy of the procedure. © 2014 The Author(s).
CITATION STYLE
Bielińska, A., Korkosz, M., Gąsowski, J., Tomaszuk, M., Staszczak-Sowa, A., Kwaśny-Krochin, B., … Grodzicki, T. (2014). Yttrium-90 distribution following radiosynoviorthesis of the knee joint in rheumatoid arthritis patients: A SPECT/CT study. Annals of Nuclear Medicine, 28(7), 688–692. https://doi.org/10.1007/s12149-014-0827-8