Rapid communication: Effects of Steris 1™ sterilization and Cidex® ortho-phthalaldehyde high-level disinfection on durability of new-generation flexible ureteroscopes

33Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background and Purpose: The effects of commonly used reprocessing methods on flexible ureteroscope longevity have never been examined. We prospectively studied the effects of Steris 1™ sterilization and Cidex® ortho-phthalaldehyde (OPA) high-level disinfection (HLD) on the image quality, physical structure, and deflective properties of two new flexible ureteroscopes. Materials and Methods: Two identical "out-of-the-box" Storz 11278AU1 flexible ureteroscopes (Karl Storz Endoscopy, Tuttlingen, Germany) were sterilized individually using the Steris 1™ system (Steris Mentor, Ohio) or disinfected with Cidex® OPA (Advanced Sterilization Products, J&J, Irvine, CA) for 100 trials followed by a crossover to the other method for another 100 trials over a period of 1 year. After every five trials, optical quality, angle of deflection, and fiber damage were analyzed in the laboratory. Throughout the study, neither of these ureteroscopes was used clinically. Results: After 100 trials, ureteroscope 1, which was sterilized initially in the Steris system, had a 12-mm tear on its shaft (noted after the 17th trial), 297 damaged fibers, and a 37% drop in resolution (loss of 3.75 lines/mm). There was no change in deflection from baseline. In contrast, after 100 cycles, ureteroscope 2, which was subjected to HLD with Cidex® OPA, had no visible external damage, a 0% change in resolution, 10 damaged fibers, and no change in deflection. After the crossover, ureteroscope 2 developed a semilunar defect that obscured the endoscopic view, whereas there was no further significant damage to ureteroscope 1. Conclusion: After 100 cycles, the Steris 1 system rendered the flexible ureteroscope unusable, whereas HLD with Cidex® OPA had minimal adverse impact. © 2007 Mary Ann Liebert, Inc.

Cite

CITATION STYLE

APA

Abraham, J. B. A., Abdelshehid, C. S., Lee, H. J., Box, G. N., Deane, L. A., Le, T., … Clayman, R. V. (2007). Rapid communication: Effects of Steris 1TM sterilization and Cidex® ortho-phthalaldehyde high-level disinfection on durability of new-generation flexible ureteroscopes. Journal of Endourology, 21(9), 985–992. https://doi.org/10.1089/end.2007.0181

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free