Abstract

The objective of this study was to compare the sensitivity and specificity of an enzyme immunoassay employing antibodies bound to a microtiter plate (MPEIA) with those of two radioimmunoassays for screening postmortem blood from selected coroner's cases for drugs of abuse. The radioimmunoassays were a coated-tube radioimmunoassay (CTRIA) and a double antibody radioimmunoassay (DARIA). Specimens consisted of 260 postmortem blood specimens from coroner's cases. Immunoassay results (positive or negative) were compared with confirmed results on those cases by gas chromatography-mass spectrometry, alone or in combination with gas-liquid chromatography using either a nitrogen-phosphorus or flame-ionization detector. Sensitivity was calculated as the true-positive rate using chromatographic confirmation as the reference standard. Specificity was calculated as the true-negative rate. Sensitivity and specificity were calculated for 5-7 potential cutoff concentrations for the drug classes opiates, amphetamines, cocaine and metabolites, and barbiturates. For opiates, the sensitivity and specificity were 99% and 93%, respectively, for the MPEIA at a cutoff of 20-ng/mL morphine, compared with 94% and 96% for the CTRIA at a cutoff of 5-ng/mL morphine and >99% and 96% for the DARIA at 20- ng/mL morphine. For cocaine and metabolites, the sensitivity and specificity were 96% and 93%, respectively, for the MPEIA at 50-ng/mL benzoylecgonine, compared with 93% and 96% for CTRIA at 50-ng/mL benzoylecgonine and 98% and 97% for the DARIA at 50-ng/mL benzoylecgonine. For amphetamines, the sensitivity and specificity were >99% and 91%, respectively, for the MPEIA at 25-ng/mL methamphetamine, compared with 93% and 86% for the CTRIA at 25- ng/mL methamphetamine and 83% and 89% for the DARIA at 50-ng/mL methamphetamine. For barbiturates, the sensitivity and specificity were >99% and 92%, respectively, for the MPEIA at 50-ng/mL secobarbital, compared with 91% and 87% for the CTRIA at 500-ng/mL secobarbital and 79% and 95% for the DARIA at a cutoff of 1000-ng/mL phenobarbital.

Cite

CITATION STYLE

APA

Spiehler, V. R., Collison, I. B., Sedgwick, P. R., Perez, S. L., Le, S. D., & Farnin, D. A. (1998). Validation of an automated microplate enzyme immunoassay for screening of postmortem blood for drugs of abuse. Journal of Analytical Toxicology, 22(7), 573–579. https://doi.org/10.1093/jat/22.7.573

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free