Implementasi Regulator Oksigen Otomatis berdasarkan Tingkat Pernapasan menggunakan Logika Fuzzy

  • HADIYOSO S
  • NURSANTO N
  • RIZAL A
N/ACitations
Citations of this article
51Readers
Mendeley users who have this article in their library.

Abstract

ABSTRAKOtomasi perangkat kesehatan saat ini banyak dikembangkan dengan tujuan untuk mempermudah kerja manusia sekaligus efisiensi utilitas perangkat. Pada penelitian ini, diusulkan desain prototipe sebuah regulator oksigen otomatis pada sebuah alat bantu pernafasan yang berfungsi untuk mengatur tekanan atau kadar oksigen yang dikeluarkan. Kondisi ini disesuaikan dengan tingkat pernafasan pasien. Jika tingkat pernafasan pasien diatas ambang batas maka tekanan oksigen akan dinaikkan. Melaui sensor, pernafasan pasien dideteksi yang selanjutnya diolah oleh mikrokontroler untuk dihitung rate pernafasannya. Melalui logika fuzzy, perhitungan tersebut diolah untuk proses pengambilan keputusan berapa banyak oksigen yang harus dikeluarkan. Setelah dilakukan pengujian, regulator otomatis dapat mengatur volume oksigen yang dikeluarkan sesuai dengan jumlah pernafasan pasien. Terdapat 9 buah aturan yang diimplementasikan pada sistem dalam pengaturan volume oksigen. Dimana setiap logika tersebut dapat dijalankan dengan baik oleh sistem. Tingkat akurasi yang dicapai perangkat untuk menghitung rate pernafasan mencapai 92,73%.Kata kunci: otomasi, regulator, oksigen, logika fuzzy. ABSTRACTAutomatic medical device currently developed with the aim to help the work and efficiency of the device utilities. In this research, proposed to prototype design an automatic oxygen regulator to regulate pressure or levels of oxygen. This condition is adjusted by the respiratory rate of patient. If the respiratory rate of the patient above the threshold then the oxygen pressure would be raised. Sensor detect the patient's breathing then processed by a microcontroller to count breathing rate. Through fuzzy logic, that calculations are processed for the decision process to determine how much oxygen should be given. After testing, the automatic regulator can control  the volume of oxygen according with the patient's respiratory condition. There are 9 rules that are implemented on the system for setting the volume of oxygen. Each logic rules can be run well by the system. The level accuracy of device to compute respiration rate, reached 92.73%.Keywords: automation, regulator, oxygen, fuzzy logic.

Cite

CITATION STYLE

APA

HADIYOSO, S., NURSANTO, N., & RIZAL, A. (2015). Implementasi Regulator Oksigen Otomatis berdasarkan Tingkat Pernapasan menggunakan Logika Fuzzy. ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika, 3(1), 52. https://doi.org/10.26760/elkomika.v3i1.52

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free