Estimate of serum immunoglobulin G concentration using refractometry with or without caprylic acid fractionation

61Citations
Citations of this article
127Readers
Mendeley users who have this article in their library.

Abstract

Objectives of this study were to develop a rapid calf-side test to determine serum IgG concentrations using caprylic acid (CA) fractionation, followed by refractometry of the IgG-rich supernatant and compare the accuracy of this method with results obtained using refractometry using raw serum. Serum samples (n = 200) were obtained from 1-d-old calves, frozen (-20°C), and shipped to the laboratory. Samples were allowed to thaw for 1. h at room temperature. Fractionation with CA was conducted by adding 1. mL of serum to a tube containing 45, 60, or 75. μL of CA and 0.5, 1.0, or 1.5. mL of 0.06 M acetic acid. The tube contents were mixed well, allowed to react for 1 min, and then centrifuged at 3,300 × g for 0, 10, or 20 min at 25°C. The %Brix and refractive index of the fractionated supernatant were determined using a digital refractometer. Nonfractionated serum was analyzed for %Brix (BRn), refractive index (nDn), and IgG concentration by radial immunodiffusion. The mean serum IgG concentration was 19.0 mg/mL [standard deviation (SD) = 9.7], with a range of 3.5 to 47.0 mg/mL. The mean serum BRn was 8.6 (SD = 0.91), with a range of 6.8 to 11.0. The mean serum nDn was 1.34566 (SD = 0.00140), with a range of 1.34300 to 1.34930. Serum nDn was positively correlated with IgG concentration (correlation coefficient = 0.86; n = 185). Fractionated samples treated with 1. mL 0.6 M acetic acid and 60. μL of CA and not centrifuged before analysis resulted in a strong relationship between the refractive index of the fractionated supernatant and IgG (correlation coefficient = 0.80; n = 45). Regression was used to determine cut points indicative of 10, 12, and 14 mg of IgG/mL to determine the sensitivity and specificity of refractometry to identify failure of passive transfer (serum IgG <10 mg/mL at 24 h old). The nDn were 1.34414, 1.34448, and 1.34480 to predict 10, 12, and 14 mg of IgG/mL of serum, respectively. The BRn cut points were 7.6, 7.8, and 8.0, respectively. The nDn cut points of 1.34448 and 1.34480 resulted in similar specificities (82.9%), whereas the 1.34414 cut point had a specificity of 60.0%. The BRn cut point of 7.6 and 7.8%Brix resulted in a similar percentage of correctly classified samples (89.7 and 90.8%, respectively); however, the 7.8% Brix cut point resulted in fewer false positives. These results suggest that Brix refractometry of nonfractionated calf serum provides a strong estimate of IgG concentration and 7.8% Brix may be used as the cut point to identify failure of passive transfer in 1-d-old calves. © 2013 American Dairy Science Association.

Cite

CITATION STYLE

APA

Morrill, K. M., Polo, J., Lago, A., Campbell, J., Quigley, J., & Tyler, H. (2013). Estimate of serum immunoglobulin G concentration using refractometry with or without caprylic acid fractionation. Journal of Dairy Science, 96(7), 4535–4541. https://doi.org/10.3168/jds.2012-5843

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free