Determination of axial vertebral rotation in MR images: Comparison of four manual and a computerized method

14Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

Abstract

Axial vertebral rotation (AVR) of 14 normal and 14 scoliotic vertebrae from magnetic resonance (MR) images was determined by three observers using four manual methods and a computerized method, which were based on the evaluation of vertebral symmetry in two dimensions (2D) and in three dimensions (3D). The method of Aaro and Dahlborn proved to be the manual method with the highest intra-observer (1.7°SD) and inter-observer (1.2°SD) reliabilities, and was also most in agreement with the computerized method (1.3°SD, 1.0°MAD). The computerized method yielded higher intra-observer (1.3°SD) and inter-observer (1.4°SD) reliabilities than the manual methods, indicating it to be an efficient alternative for repeatable and reliable AVR measurements. © The Author(s) 2010.

Cite

CITATION STYLE

APA

Vrtovec, T., Pernuš, F., & Likar, B. (2010). Determination of axial vertebral rotation in MR images: Comparison of four manual and a computerized method. European Spine Journal, 19(5), 774–781. https://doi.org/10.1007/s00586-010-1340-y