Behavior of the Cadmium Pool in the INL Mk-IV Electrorefiner

  • Fredrickson G
  • Horvath D
  • Yoo T
  • et al.
1Citations
Citations of this article
N/AReaders
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The Mk-IV electrorefiner has been in service since 1996 recovering uranium from spent fuels from the Experimental Breeder Rector II and Fast Flux Test Facility sodium-cooled fast reactors. The electrorefiner vessel includes a cadmium pool beneath the salt. The voltage signal between the cadmium pool and reference electrode (Ag/AgCl type) provides information about the chemical condition of the cadmium pool with respect to uranium and zirconium saturation. This information is used to guide process control and sampling decisions. This paper describes how the voltage signal is related to chemistry by the analyses of data from Mk-IV operations and confirmatory experimentation.

Cite

CITATION STYLE

APA

Fredrickson, G. L., Horvath, D. C., Yoo, T.-S., Searle, R. N., Patterson, M. N., Vaden, D., … Andersen, C. T. (2025). Behavior of the Cadmium Pool in the INL Mk-IV Electrorefiner. Journal of The Electrochemical Society, 172(12), 123502. https://doi.org/10.1149/1945-7111/ae26d5