Abstract
Background: Insulin is temperature sensitive as high temperatures reduce its potency. Refrigeration for insulin storage is still needed but households in remote areas do not have refrigerators. Also, the electricity supply is usually affected by natural disasters. We aim to examine the temperature-reducing efficacy of cooling devices in hot-humid conditions. Methods: Five cooling devices, (1) earthen jar filled with water, (2) earthen jar filled with soil, (3) two clay pots, gap filled with wet soil, (4) two clay pots, gap filled with wet sand, and (5) commercial cooling wallet were used in this study. External and internal temperatures were monitored by the temperature logger between October 2019 and September 2020 in Narathiwat, Thailand. Cooling efficacy was assessed by average absolute temperature reduction and relative cooling effect. Results: Mean external temperature and humidity were 27.3 ± 1.5 °C and 78.2 ± 7.1%RH. The mean differences between the external and internal temperatures were; device (1) −0.1 ± 0.6 °C (p = NS), (2) 0.0 ± 0.8 °C (p = NS), (3) −1.7 ± 0.9 °C (p
Author supplied keywords
Cite
CITATION STYLE
Taerahkun, S., & Sriphrapradang, C. (2022). Efficacy of alternative cooling devices used for insulin storage without refrigeration under hot-humid environment. Annals of Medicine, 54(1), 1118–1125. https://doi.org/10.1080/07853890.2022.2067355