Abstract
Negative-output KY Boost converter, which can obtain the negative output voltage and could be driven easily, is a good topology to overcome traditional Boost and Buck-Boost converters and it is believed that this converter will be widely used in engineering applications in the future. In this study, by using the averaging method and geometrical technique, the average and small signal model of the negative-output KY Boost converter are established. The DC equilibrium point and transfer functions of the system are derived and analyzed. Finally, the effectiveness of the established model and the correctness of the theoretical analysis are confirmed by the circuit experiment. © 2014 Faqiang Wang et al.
Cite
CITATION STYLE
Wang, F., Li, J., & Ma, X. (2014). Average and small signal modeling of negative-output KY boost converter in CCM operation. Mathematical Problems in Engineering, 2014. https://doi.org/10.1155/2014/810956