Influence of moisture content on electromagnetic response of concrete studied using a homemade apparatus

9Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

Abstract

In this study, we examined the influence of moisture content on the electromagnetic response of concrete. A novel homemade electromagnetic monitoring apparatus was developed and used to evaluate the Hall effect voltage at both ends of concrete based on our previous study of the Hall effect. We used four different concrete mix water/binder ratios: 0.30, 0.28, 0.26, and 0.24, and three conditions (relative humidity, carbonation, and water absorption) were examined in this experiment. The results show that the moisture content inside concrete influences the relative permeability of concrete. The variation in the Hall effect voltage is more influenced by carbonation than changes in relative humidity; water absorption increases the Hall effect voltage the least amongst the other examined factors. According to the experiment, a calibration system was established, and the relevant correction factors are provided.

Cite

CITATION STYLE

APA

Li, Z., Jin, Z., Shao, S., Zhao, T., & Wang, P. (2019). Influence of moisture content on electromagnetic response of concrete studied using a homemade apparatus. Sensors (Switzerland), 19(21). https://doi.org/10.3390/s19214637