Optimal Common-Mode Voltage Injection for Phase-Modular Three-Phase PFC Rectifiers Minimizing Energy Buffering Requirement

8Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Realizing an isolated three-phase Power Factor Correction (PFC) ac-dc converter as a phase-modular system, i.e., by star-connecting three single-phase PFC rectifier front-ends with individual isolated dc-dc converter stages generating a common dc output voltage advantageously facilitates the use of standard single-phase converter modules. Further the low dc-link voltage level of typically 400V (for a grid with 23Vrms line-to-neutral voltage) allows to employ high performance 600V power semiconductors. The main drawback of this concept, however, is the fact that the time-varying single-phase input power only sums to a constant three-phase output power at the isolated dc output, such that large dc-link capacitor values are required in each module (in the range of several 100μF for a 6kW system), thereby limiting the achievable power density. It is known from literature that the dc-link energy buffering requirement Δ Edc can be reduced by means of a third-harmonic common-mode (CM) voltage injection modulation and this article identifies the optimal CM voltage waveform with respect to minimizing ΔEdc, i.e., reducing ΔEdc to the theoretical minimum by combining a brute-force evaluation of the time-domain CM voltage waveform with phase-symmetry considerations. Additionally, converter operation with minimum dc-link voltage and/or dc-link capacitor values is analyzed and a saturable grid current controller allowing operation of the PFC rectifier front-ends with the optimal CM voltage waveform is investigated. Experimental results with a 6kW prototype system yield a reduction in ΔEdc by up to 42% (compared to conventional sinusoidal modulation), which closely matches the theoretical prediction. Also, PFC rectifier operation with a dc-link voltage level as low as 285V (i.e., below the 325Vpk grid line-to-neutral voltage amplitude) and with ultra-low dc-link capacitor values is demonstrated.

Cite

CITATION STYLE

APA

Menzi, D., Marugg, V., Langbauer, T., & Kolar, J. W. (2023). Optimal Common-Mode Voltage Injection for Phase-Modular Three-Phase PFC Rectifiers Minimizing Energy Buffering Requirement. IEEE Open Journal of Power Electronics, 4, 674–686. https://doi.org/10.1109/OJPEL.2023.3308904

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free