Satoh’s equation (Satoh et al., 1991) was modified to estimate the power consumption in gas–liquid stirred vessels with various types of impellers. Npand f was added in order to use a correlation equation widely (f: correction factor for special shaped impeller and large scale impellers, Np: power number without aeration). Power consumption was correlated by the following equation. (Formula present) The value of β was about 1.2 to 1.3 for general impellers (disk turbine, pitched disk turbine, flat paddle and pitched paddle) and about 1.2 for large scale impellers (MAXBLEND™ and FULLZONE™). By using this equation, the power consumption of general impellers and large scale impellers can be presumed with sufficient accuracy.
CITATION STYLE
Aida, M., & Shono, A. (2014). Estimation of power consumption in gas-liquid stirred vessels with various types of impellers. Kagaku Kogaku Ronbunshu, 40(5), 366–371. https://doi.org/10.1252/kakoronbunshu.40.366