Effects of Mechanical Performance on Deliverability and Dose Distribution by Comparing Multi Institutions’ Knowledge-based Models for Prostate Cancer in Volumetric Modulated Arc Therapy

2Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Background/Aim: The aim of this study was to evaluate the mechanical performance and the effect on dose distribution and deliverability of volumetric modulated arc therapy (VMAT) plans for prostate cancer created with the commercial knowledge-based planning (KBP) system (RapidPlan™). Materials and Methods: Three institutions, A, B, and C were enrolled in this study. Each institution established and trained a KBP model with their own cases. CT data and structures for 45 patients at institution B were utilized to validate the dose-volume parameters (D2(%), D95(%), and D98(%) for target, and V50(%), V75(%), and V90(%) for rectum and bladder), and the following mechanical performance parameters and gamma passing rates of each KBP model: leaf sequence variability (LSV), aperture area variability (AAV), total monitor unit (MU), modulation complexity score for VMAT (MCSv), MU/control point (CP), aperture area (AA)/CP, and MU×AA/CP. Results: Significant differences (p<0.01) in dosimetric parameters such as D2 and D98 for target and V50, V75 and V90 for bladder were, observed among the three institutions. The means and standard deviations of MCSv were 0.31±0.03, 0.29±0.02, and 0.32±0.03, and the angles of maximum and minimum MU×AA/CP were 269◦ and 13◦, 269◦ and 13◦, and 273◦ and 153◦ at institutions A, B, and C, respectively. The mean gamma passing rate (1%/1 mm.) was >95% for all cases in each institution. Dose distribution and mechanical performance significantly differed between the three models. Conclusion: Each KBP model had different dose distributions and mechanical performance but could create an acceptable plan for deliverability regardless of mechanical performance.

Cite

CITATION STYLE

APA

Tsuru, H., Ueda, Y., Tamura, M., Monzen, H., Ohira, S., Masaoka, A., … Koizumi, M. (2022). Effects of Mechanical Performance on Deliverability and Dose Distribution by Comparing Multi Institutions’ Knowledge-based Models for Prostate Cancer in Volumetric Modulated Arc Therapy. In Vivo, 36(2), 687–693. https://doi.org/10.21873/INVIVO.12754

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free