Mesh brachytherapy is a special type of a permanent brachytherapy implant: it uses low-energy radioactive seeds in an absorbable mesh that is sutured onto the tumor bed immediately after a surgical resection. This treatment offers low additional risk to the patient as the implant procedure is carried out as part of the tumor resection surgery. Mesh brachytherapy utilizes identification of the tumor bed through direct visual evaluation during surgery or medical imaging following surgery through radiographic imaging of radio-opaque markers within the sources located on the tumor bed. Thus, mesh brachytherapy is customizable for individual patients. Mesh brachytherapy is an intraoperative procedure involving mesh implantation and potentially real-time treatment planning while the patient is under general anesthesia. The procedure is multidisciplinary and requires the complex coordination of multiple medical specialties. The preimplant dosimetry calculation can be performed days beforehand or expediently in the operating room with the use of lookup tables. In this report, the guidelines of American Association of Physicists in Medicine (AAPM) are presented on the physics aspects of mesh brachytherapy. It describes the selection of radioactive sources, design and preparation of the mesh, preimplant treatment planning using a Task Group (TG) 43-based lookup table, and postimplant dosimetric evaluation using the TG-43 formalism or advanced algorithms. It introduces quality metrics for the mesh implant and presents an example of a risk analysis based on the AAPM TG-100 report. Recommendations include that the preimplant treatment plan be based upon the TG-43 dose calculation formalism with the point source approximation, and the postimplant dosimetric evaluation be performed by using either the TG-43 approach, or preferably the newer model-based algorithms (viz., TG-186 report) if available to account for effects of material heterogeneities. To comply with the written directive and regulations governing the medical use of radionuclides, this report recommends that the prescription and written directive be based upon the implanted source strength, not target-volume dose coverage. The dose delivered by mesh implants can vary and depends upon multiple factors, such as postsurgery recovery and distortions in the implant shape over time. For the sake of consistency necessary for outcome analysis, prescriptions based on the lookup table (with selection of the intended dose, depth, and treatment area) are recommended, but the use of more advanced techniques that can account for real situations, such as material heterogeneities, implant geometric perturbations, and changes in source orientations, is encouraged in the dosimetric evaluation. The clinical workflow, logistics, and precautions are also presented.

Author supplied keywords

Cite

CITATION STYLE

APA

Feng, W., Rivard, M. J., Carey, E. M., Hearn, R. A., Pai, S., Nath, R., … Zhang, H. (2021). Recommendations for intraoperative mesh brachytherapy: Report of AAPM Task Group No. 222. Medical Physics, 48(11), e969–e990. https://doi.org/10.1002/mp.15191

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free