Vxg pattern-based analysis and battery deterioration diagnosis

3Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

This paper presents the results of an analysis using the direct current internal resistance (DCIR) method on a nickel-cobalt-manganese oxide (NCM)-based battery with a nominal capacity of 55.6 Ah. The accelerated degradation test was performed on V0G, V1G, and V2G patterns, repre-senting existing simple power supply, smart charging control, and bi-directional charge/discharge control, respectively. We assumed V0G, V1G, and V2G patterns and conducted charging and dis-charging experiments according to the set conditions. According to the pattern repetition, changes in the internal resistance of DCIR and AC-impedance were analyzed and battery deterioration was diagnosed. By comparing DCIR and AC-impedance, we confirmed that the changes in internal resistance has a similar trend. In particular, we propose a new DCIR analysis method in the “stop-operation” part rather than the traditional DCIR method. In the case of traditional DCIR method, time is required for the battery to stabilize. However, the newly proposed DCIR analysis method has the advantage of diagnosing the deterioration of the battery during system operation by analyzing the internal resistance without the stabilization time of the battery.

Cite

CITATION STYLE

APA

Lim, J., Lee, S. E., Park, K. Y., Kim, H. S., & Choi, J. H. (2021). Vxg pattern-based analysis and battery deterioration diagnosis. Energies, 14(17). https://doi.org/10.3390/en14175422

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free