Using a harmonic scalpel ''drilling and clamping'' method to implement zero ischemic robotic-Assisted partial nephrectomy: An observation case report study

7Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

Abstract

Robot-Assisted partial nephrectomy (RAPN) has gradually become a popular minimally invasive nephron-sparing surgical option for small renal tumors. Ischemic injury should be minimized because it impacts renal function outcomes following partial nephrectomy. Herein, the authors detail the technique and present initial perioperative outcomes of our novel harmonic scalpel ''drilling and clamping'' method to implement zero-ischemic RAPN. The authors prospectively collected baseline and perioperative data of patients who underwent zero ischemic RAPN performed byour harmonic scalpel ''drilling and clamping''method.From April 2012 to December 2014, a total of 19 consecutive zero ischemic RAPN procedures were performed by a single surgeon. For 18 of the 19 patients, RAPN using our harmonic scalpel ''Drilling and Clamping'' method was successfully completed without the need for hilar clamping. Themediantumor sizewas 3.4 cm(range: 1.8-6.2); operative timewas3.2 hours (range: 1.9-4.5); blood loss was 100mL (range: 30-950); and postoperative hospital stay was 4 days (3-26). One patient required intraoperative blood transfusion. Two patients had intra or postoperative complications: 1 was converted to traditional laparotomy because of massive bleeding, whereas another had postoperative stress ulcer. Pathology confirmed renal cell carcinoma in 13 patients (63.2%), angiomyolipoma in 6 patients: (31.5%), and oncocytoma in 1 patient (5.3%). Mean pre-and postoperative serum creatinine (0.82mg/dL and 0.85mg/dL, respectively), estimated glomerular filtration rate (84.12 and 82.18, respectively), and hemoglobin (13.27 g/dL and 12.71 g/dL, respectively) were comparable. The authors present a novel zero-ischemic technique for RAPN. They believe that this technique is feasible and reproducible.

Cite

CITATION STYLE

APA

Hou, C. P., Lin, Y. H., Hsu, Y. C., Chen, C. L., Chang, P. L., & Tsui, K. H. (2016). Using a harmonic scalpel “‘drilling and clamping’” method to implement zero ischemic robotic-Assisted partial nephrectomy: An observation case report study. Medicine (United States), 95(3). https://doi.org/10.1097/MD.0000000000002349

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free