The behavior of a stiffened beam seat when it is attached to a column web rather than the flange is investigated to make design recommendations. AISC developed a procedure for calculating the capacity of stiffened seats attached to the flange and tables to aid the designer. The application of these tables for the case of the web attachment is analyzed.
CITATION STYLE
Ellifritt, D. S., & Sputo, T. (1999). Design criteria for stiffened seated connections to column webs. Engineering Journal, 36(4), 160–168. https://doi.org/10.62913/engj.v37i1.735