A low vaginal "pool" amniotic fluid glucose measurement is a predictive but not a sensitive marker for infection in women with preterm premature rupture of membranes

13Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: We sought to identify the use of vaginal amniotic fluid (vAF) glucose measurements in predicting infection of the amniotic fluid retrieved by transabdominal amniocentesis (aAF) in women with preterm premature rupture of the membranes (PPROM). Study design: Fluid was retrieved by aAF was retreived from 35 consecutive women with PPROM on whom an amniocentesis was clinically indicated to rule out intra-amniotic infection/inflammation and successfully completed. aAF was cultured for aerobic, anaerobic bacteria, Ureaplasma and Mycoplasma species. Clinical laboratory analysis for aAF included glucose concentration, Gram stain, lactate dehydrogenase, and white and red blood cell count. vAF was analyzed only for glucose concentration. Glucose concentration for the paired abdominal-vaginal AF samples (aAF-vAF) was determined by using well-established clinical and research laboratory methods. At the end of enrollment we stratified our patients into 2 groups: (1) positive microbial cultures (+)AFC (n = 17, gestational age [GA]: 27.3 ± 0.7 weeks) or (2) negative microbial cultures (-)AFC (n = 18, GA: 31.3 ± 0.5 weeks). Cohen kappa measure of concordance and receiver operating characteristic (ROC) curve analysis were used to test the ability of the vaginal "pool" glucose measurements to discriminate between women with positive or negative AF cultures. Results: Women with (+)AFC ruptured and delivered at an earlier GA compared with the (-)AFC group (p < .001). The latency period was similar (P = .35). There was a significant linear correlation between aAF and vAF glucose concentrations (r = 0.783, P

Cite

CITATION STYLE

APA

Buhimschi, C. S., Sfakianaki, A. K., Hamar, B. G., Pettker, C. M., Bahtiyar, M. O., Funai, E., … Buhimschi, I. A. (2006). A low vaginal “pool” amniotic fluid glucose measurement is a predictive but not a sensitive marker for infection in women with preterm premature rupture of membranes. American Journal of Obstetrics and Gynecology, 194(2), 309–316. https://doi.org/10.1016/j.ajog.2005.07.070

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free