Assessing the ability of the Fitbit Charge 2 to accurately predict VO2max

17Citations
Citations of this article
58Readers
Mendeley users who have this article in their library.

Abstract

Background: The aim of this study was to assess the ability of the Fitbit Charge 2 (FBC2) to accurately estimate VO2max in comparison to both the gold standard VO2max test and a non-exercise VO2max prediction equation. Methods: Thirty healthy subjects (17 men, 13 women) between the ages of 18 and 35 (age =21.7±3.1 years) were given a FBC2 to wear for seven days and followed instructions on how to obtain a cardio fitness score (CFS). VO2max was measured with an incremental test on the treadmill followed by a verification phase. VO2max was predicted via a non-exercise prediction model (N-Ex) using self-reported physical activity level. Results: Measured VO2max was significantly lower than FBC2 predicted CFS (VO2max =49.91±6.83; CFS =52.53±8.43, P=0.03). N-Ex prediction was significantly lower than CFS but not significantly lower than measured VO2max (N-Ex =48.79±6.32; CFS vs. N-Ex: P=0.01; VO2max vs. N-Ex: P=0.54). Relationships between both VO2max vs. CFS and VO2max vs. N-Ex were good (ICC: VO2max vs. CFS=0.87, VO2max vs. N-Ex =0.87); Bland-Altman analysis indicated consistency of CFS measurement and lack of bias. The coefficient of variation (CV) and mean absolute percent error (MAPE) were greater with CFS than N-Ex (CV: CFS =6.5%±4.1%, N-Ex =5.6%±3.6%; MAPE: CFS =10.2%±6.7%, N-Ex =7.8%±5.0%). Heart rate (HR) estimated by the FBC2 was lower than estimated (Est) HR for pace based on HR extrapolation (FBC2 =155±18 bpm, Est =183±15 bpm, P<0.001). The difference in CFS and VO2max was inversely correlated with the difference in FBC2 HR and Estimated HR (r =−0.45, P<0.001). Conclusions: The FBC2 shows consistent, unbiased measurement of CFS while overestimating VO2max in healthy men and women. The non-exercise VO2max prediction equation provides a similar, slightly more accurate, VO2max prediction than the CFS without the need for an exercise test or purchase of a Fitbit.

Cite

CITATION STYLE

APA

Freeberg, K. A., Baughman, B. R., Vickey, T., Sullivan, J. A., & Sawyer, B. J. (2019). Assessing the ability of the Fitbit Charge 2 to accurately predict VO2max. MHealth, 5. https://doi.org/10.21037/mhealth.2019.09.07

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free