Abstract
Lasnex calculations and x-ray flux measurements are presented for a series of NIF vacuum hohlraum experiments that were among the first targets shot on NIF as part of the facility commissioning. An important result is that the hohlraum x-ray fluxes are significantly higher than predicted by pre-shot Lasnex calculations employing the baseline "configuration managed" physics packages used in the NIF ignition target calculations. A possible explanation for the high-flux vacuum hohlraum result has been explored via post-shot calculations in which non-baseline emissivity and heat conduction models are used. © 2010 IOP Publishing Ltd.
Cite
CITATION STYLE
Olson, R. E., Suter, L. J., Kline, J. L., Callahan, D. A., Rosen, M. D., Widmann, K., … Glenzer, S. H. (2010). Lasnex simulations of NIF vacuum hohlraum commissioning experiments. In Journal of Physics: Conference Series (Vol. 244). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/244/3/032057