Real-time flow assessment: From model to patients

  • Traber J
  • Wurche L
  • Dieringer M
  • et al.
N/ACitations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: In stratification of heart valve diseases blood flow assessment often plays a key role. When echocardiography struggles, phase contrast magnetic resonance imaging (PC-MRI) may be considered as an alternative (Srichai et al. AJR 2009). Arrhythmias are a major limitation of conventional segmented PC-MRI (SEG). Real-time sequences (RT) could overcome it. The purpose of this study is to evaluate RT in a flow model as well as in volunteers and patients. We hypothesize to measure equal velocities and flow compared to SEG as reference in sinus rhythm and aimed to show feasibility in atrial fibrillation (Afib). Methods: In a flow model (I), volunteers and prospectively enrolled patients (II) we compared a highly accelerated RT (temp. res. 40 ms, TE 5.6 ms, ETL 7, T-PAT 3null, matrix 128null104px) using shared velocity encoding (Lin et al. MRM 2009) with SEG (temp. res. 48 ms, TE 2.3 ms, ETL 5, I-PAT 2null, matrix 192null156px) on a 1.5 T scanner (Avanto, Siemens Healthcare, Germany) with a 12 channel cardiac coil. I The model generated adjustable constant flow. 81 PC images were acquired 25 mm from an interchangeable aortic stenosis-like narrowing with different areas (0.6 cm2, 1.3 cm2, 2.0 cm2) perpendicular to tube running (Figure 1). II In vivo studies were measured at sinotubular junction perpendicular to the aorta. We quantified (cvi42, Circle CVI, Canada) with equalized voxel size: in I mean velocity and flow in II mean peak velocity, stroke volume and regurgitation fraction In patients with Afib only RT was applied. Results: I All PC images were acquired successfully and evaluable. Mean velocities ranged 35-216 cm/s (SEG). Scatter plots showed good correlations between SEG and RT (velocity: r = 0.991, p < 0.0005; flow: r > 0.993, p < 0.0005). Flow in RT partially strayed to higher values, although differences were not significant (122 (plus or minus) 72 ml/s vs. 143 (plus or minus) 74 ml/s; p = 0.290). II We included 119 subjects: 52 healthy subjects (28 men, 51 (plus or minus) 19 y) as well as patients (55 men, 66 (plus or minus) 15 y) with aortic valve disease (60) and/or Afib (8). RT acquisition failed in one, image quality was non-diagnostic in three cases. Peak velocities ranged 64-373 cm/s (SEG). Scatter plots showed reasonable correlations between SEG and RT (velocity: r = 0.964, p < 0.0005; stroke volume r = 0.880, p < 0.0005). Velocities in RT partially strayed to lower values on high reference velocities, although differences were not significant (164 (plus or minus) 71 cm/s vs. 153 (plus or minus) 60 cm/s; p = 0.206). Stray bullets had at least moderate aortic valve stenosis. In patients with aortic valve insufficiency (47), regurgitation fractions correlated well (r = 0,937; p = 0,0005). In Afib patients PC-RT was feasible in all patients and flow-time plots showed frequency-dependent variability of stroke volumes (Figure 2). Conclusions: The evaluated real-time PC sequence can access flow reliably and in good correlation to a conventional segmented version in model experiments, volunteers and patients. Hence it might become an useful alternative to doppler echocardiography in arrhythmic patients. (Figure Presented).

Cite

CITATION STYLE

APA

Traber, J., Wurche, L., Dieringer, M. A., Utz, W., Greiser, A., Jin, N., … Schulz-Menger, J. (2014). Real-time flow assessment: From model to patients. Journal of Cardiovascular Magnetic Resonance, 16, P386. https://doi.org/10.1186/1532-429x-16-s1-p386

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free