Abstract
This is an observational case series of 15 patients with full-thickness traumatic wound defects treated with a dermal substitute. There were 8 male and 7 female patients with a mean age of 36.6 years. Eight patients had trauma to the lower limbs and 7 were of the upper limbs, with the average lesion size 104.4 cm2 (range 6-490 cm2). The time to complete healing had a mean average time of 26.8 days (range 16-60 days). All patients went on to successful repair with 6 patients requiring a second application of the substitute and 5 patients needing split thickness skin grafts. Infection was recorded in one patient. © 2013 The Author(s).
Author supplied keywords
Cite
CITATION STYLE
Vaienti, L., Marchesi, A., Palitta, G., Gazzola, R., Parodi, P. C., & Leone, F. (2013). Limb trauma: The use of an advanced wound care device in the treatment of full-thickness wounds. Strategies in Trauma and Limb Reconstruction, 8(2), 111–115. https://doi.org/10.1007/s11751-013-0165-8