Interobserver Agreement Rates on C-X-C Motif Chemokine Receptor 4-Directed Molecular Imaging and Therapy

6Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background We aimed to evaluate the interobserver agreement rates in patients scanned with C-X-C motif chemokine receptor 4 (CXCR4)-directed PET/CT, including the rate of patients eligible for CXCR4-targeted radioligand therapy (RLT) based on scan results. Methods Four independent observers reviewed 50 CXCR4-targeted [68Ga]pentixafor PET/CT of patients with various solid cancers. On a visual level, the following items were assessed by each reader: overall scan impression, number of organ and lymph node (LN) metastases and number of affected organs and LN regions. For a quantitative investigation, readers had to choose a maximum of 3 target lesions, defined as largest in size and/or most intense uptake per organ compartment. Reference tissues were also quantified, including unaffected hepatic parenchyma and blood pool. Last, all observers had to decide whether patients were eligible for CXCR4-targeted RLT. Concordance rates were tested using intraclass correlation coefficients (ICCs). For interpretation, we applied the definition of Cicchetti (with 0.4-0.59 indicating fair; 0.6-0.74, good; 0.75-1, excellent agreement). Results On a visual level, fair agreement was achieved for an overall scan impression (ICC, 0.58; 95% confidence interval, 0.45-0.71). Organ and LN involvement (ICC, ≥0.4) demonstrated fair, whereas CXCR4 density and number of LN and organ metastases showed good agreement rates (ICC, ≥0.65). Number of affected organs and affected LN areas, however, showed excellent concordance (ICC, ≥0.76). Quantification in LN and organ lesions also provided excellent agreement rates (ICC, ≥0.92), whereas quantified uptake in reference organs provided fair concordance (ICC, ≥0.54). Again, excellent agreement rates were observed when deciding on patients eligible for CXCR4-RLT (ICC, 0.91; 95% confidence interval, 0.85-0.95). Conclusions In patients scanned with CXCR4-targeted PET/CT, we observed fair to excellent agreement rates for both molecular imaging and therapy parameters, thereby favoring a more widespread adoption of [68Ga]pentixafor in the clinic.

Cite

CITATION STYLE

APA

Hartrampf, P. E., Kosmala, A., Serfling, S. E., Bundschuh, L., Higuchi, T., Lapa, C., … Werner, R. A. (2023). Interobserver Agreement Rates on C-X-C Motif Chemokine Receptor 4-Directed Molecular Imaging and Therapy. Clinical Nuclear Medicine, 48(6), 483–488. https://doi.org/10.1097/RLU.0000000000004629

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free