Comparison of same day diagnostic tools including Gene Xpert and unstimulated IFN-γ for the evaluation of pleural tuberculosis: A prospective cohort study

56Citations
Citations of this article
113Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The accuracy of currently available same-day diagnostic tools (smear microscopy and conventional nucleic acid amplification tests) for pleural tuberculosis (TB) is sub-optimal. Newer technologies may offer improved detection.Methods: Smear-microscopy, adenosine deaminase (ADA), interferon gamma (IFN-γ), and Xpert MTB/RIF [using an unprocessed (1 ml) and centrifuged (~20 ml) sample] test accuracy was evaluated in pleural fluid from 103 consecutive patients with suspected pleural TB. Culture for M.tuberculosis and/or histopathology (pleural biopsy) served as the reference standard. Patients were followed prospectively to determine their diagnostic categorisation.Results: Of 93 evaluable participants, 40 had definite-TB (reference positive), 5 probable-TB (not definite but treated for TB) and 48 non-TB (culture and histology negative, and not treated for TB). Xpert MTB/RIF sensitivity and specificity (95% CI) was 22.5% (12.4 - 37.6) and 98% (89.2 - 99.7), respectively, and centrifugation did not improve sensitivity (23.7%). The Xpert MTB/RIF internal positive control showed no evidence of inhibition. Biomarker specific sensitivity, specificity, PPV, and NPVs were: ADA (48.85 IU/L; rule-in cut-point) 55.3% (39.8 - 69.9), 95.2% (83.9 - 98.7), 91.4 (73.4 - 95.4), 69.7% (56.7 - 80.1); ADA (30 IU/L; clinically used cut-point) 79% (63.7 - 89), 92.7% (80.6 - 97.5), 91.0 (73.4 - 95.4), 82.7% (69.3 - 90.1); and IFN-γ (107.7 pg/ml; rule-in cut-point) 92.5% (80.2 - 97.5), 95.9% (86.1 - 98.9), 94.9% (83.2 - 98.6), 93.9% (83.5 - 97.9), respectively (IFN-γ sensitivity and NPV better than Xpert [p < 0.05] and rule-in ADA [p < 0.05]).Conclusion: The usefulness of Xpert MTB/RIF to diagnose pleural TB is limited by its poor sensitivity. IFN-γ is an excellent rule-in test and, compared to ADA, has significantly better sensitivity and rule-out value in a TB-endemic setting. © 2014 Meldau et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Meldau, R., Peter, J., Theron, G., Calligaro, G., Allwood, B., Symons, G., … Dheda, K. (2014). Comparison of same day diagnostic tools including Gene Xpert and unstimulated IFN-γ for the evaluation of pleural tuberculosis: A prospective cohort study. BMC Pulmonary Medicine, 14(1). https://doi.org/10.1186/1471-2466-14-58

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free