Flywheel calibration of a continuous-wave coherent Doppler wind lidar

4Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

Abstract

A rig for calibrating a continuous-wave coherent Doppler wind lidar has been constructed. The rig consists of a rotating flywheel on a frame together with an adjustable lidar telescope. The laser beam points toward the rim of the wheel in a plane perpendicular to the wheel s rotation axis, and it can be tilted up and down along the wheel s periphery and thereby measure different projections of the tangential speed. The angular speed of the wheel is measured using a high-precision measuring ring fitted to the periphery of the wheel and synchronously logged together with the lidar speed. A simple geometrical model shows that there is a linear relationship between the measured line-of-sight speed and the beam tilt angle, and this is utilised to extrapolate to the tangential speed as measured by the lidar. An analysis of the uncertainties based on the model shows that a standard uncertainty on the measurement of about 0.1% can be achieved, but also that the main source of uncertainty is the width of the laser beam and its associated uncertainty. Measurements performed with different beam widths confirm this. Other measurements with a minimised beam radius show that themethod in this case performs about equally well for all the tested reference speeds ranging from about 3 to 18ms-1.

Cite

CITATION STYLE

APA

Tegtmeier Pedersen, A., & Courtney, M. (2021). Flywheel calibration of a continuous-wave coherent Doppler wind lidar. Atmospheric Measurement Techniques, 14(2), 889–903. https://doi.org/10.5194/amt-14-889-2021

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free