Analysis of the Impact of High-Space Building Heating System Solutions on Building Energy Efficiency

1Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The existence of stratification in high-ceiling buildings is real, but not visible or easy noticeable by humans. For field measurements, the Prayer House – The Kaunas Basilica of the Resurrection of Christ, located in Kaunas, Lithuania, was chosen, in which the temperature distribution at different heights (6 m, 8 m, 10 m, 12 m, 14 m, 16 m and 18 m) during the heating season was observed. The Basilica had radiant heaters installed at 5 m height. According to the plan of the Prayer House, CFD model was created, and the temperature distribution of the different heating (radiant heating and floor heating) systems were compared. The IDA-ICE modelling of energy consumption was conducted using the CFD results as a basis, and the economic analysis was performed based on the obtained results. The study confirmed the existence of stratification in high-ceiling buildings.

Cite

CITATION STYLE

APA

Vestfal, P., Černeckienė, J., & Šeduikytė, L. (2023). Analysis of the Impact of High-Space Building Heating System Solutions on Building Energy Efficiency. Journal of Sustainable Architecture and Civil Engineering, 33(2), 113–121. https://doi.org/10.5755/j01.sace.33.2.34305