Determination of silver(I) by differential pulse voltammetry using a glassy carbon electrode modified with synthesized N-(2-aminoethyl)-4,4'-bipyridine

35Citations
Citations of this article
47Readers
Mendeley users who have this article in their library.

Abstract

A new modified glassy carbon electrode (GCE) based on a synthesized N-(2-aminoethyl)-4,4'-bipyridine (ABP) was developed for the determination of Ag(I) by differential pulse voltammetry (DPV). ABP was covalently immobilized on GC electrodes surface using 4-nitrobenzendiazonium (4-NBD) and glutaraldehyde (GA). The Ag(I) ions were preconcentrated by chemical interaction with bipyridine under a negative potential (-0.6 V); then the reduced ions were oxidized by differential pulse voltammetry and a peak was observed at 0.34 V. The calibration curve was linear in the concentration range from 0.05 μM to 1 μM Ag(I) with a detection limit of 0.025 μM and RSD = 3.6%, for 0.4 μM Ag(I). The presence of several common ions in more than 125-fold excess had no effect on the determination of Ag(I). The developed sensor was applied to the determination of Ag(I) in water samples using a standard addition method. © 2010 by the authors.

Cite

CITATION STYLE

APA

Radulescu, M. C., Chira, A., Radulescu, M., Bucur, B., Bucur, M. P., & Radu, G. L. (2010). Determination of silver(I) by differential pulse voltammetry using a glassy carbon electrode modified with synthesized N-(2-aminoethyl)-4,4’-bipyridine. Sensors, 10(12), 11340–11351. https://doi.org/10.3390/s101211340