Pulse wave response characteristics for thickness and hardness of the cover layer in pulse sensors to measure radial artery pulse

14Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Piezo-resistive pressure sensors are widely used for measuring pulse waves of the radial artery. Pulse sensors are generally fabricated with a cover layer because pressure sensors without a cover layer are fragile when they come into direct contact with the skin near the radial artery. However, no study has evaluated the dynamic pulse wave response of pulse sensors depending on the thickness and hardness of the cover layer. This study analyzed the dynamic pulse wave response according to the thickness and hardness of the cover layer and suggests an appropriate thickness and hardness for the design of pulse sensors with semiconductor device-based pressure sensors. Methods: Pulse sensors with 6 different cover layers with various thicknesses (0.8mm, 1mm, 2mm) and hardnesses (Shore type A; 30, 43, 49, 71) were fabricated. Experiments for evaluating the dynamic pulse responses of the fabricated sensors were performed using a pulse simulator to transmit the same pulse wave to each of the sensors. To evaluate the dynamic responses of the fabricated pulse sensors, experiments with the pulse sensors were conducted using a simulator that artificially generated a constant pulse wave. The pulse wave simulator consisted of a motorized cam device that generated the artificial radial pulse waveform by adjusting the stroke of the cylindrical air pump and an air tube that conveyed the pulse to the artificial wrist. Results: The amplitude of the measured pulse pressure decreased with increasing thickness and hardness of the cover layer. Normalized waveform analysis showed that the thickness rather than the hardness of the cover layer contributed more to waveform distortion. Analysis of the channel distribution of the pulse sensor with respect to the applied constant dynamic pressure showed that the material of the cover layer had a large effect. Conclusions: In this study, in-line array pulse sensors with various cover layers were fabricated, the dynamic pulse wave responses according to the thickness and the hardness of the cover layer were analyzed, and an appropriate thickness and hardness for the cover layer were suggested. The dynamic pulse wave responses of pulse sensors revealed in this study will contribute to the fabrication of improved pulse sensors and pulse wave analyses.

Cite

CITATION STYLE

APA

Jun, M. H., Jeon, Y. J., Cho, J. H., & Kim, Y. M. (2018). Pulse wave response characteristics for thickness and hardness of the cover layer in pulse sensors to measure radial artery pulse. BioMedical Engineering Online, 17(1). https://doi.org/10.1186/s12938-018-0551-z

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free