Gas permeability of partially hydrated geosynthetic clay liner under two stress conditions

45Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

Abstract

The results of a series of gas permeability tests, with monitoring of gravimetric/volumetric moisture content and total suction, on a commercially available needle-punched geosynthetic clay liner (GCL) are presented. GCL specimens were partially hydrated with deionised water under 2 and 20 kPa confinement prior to testing. The tests were conducted at differential pressures ranging from 1 to 10 kPa. Gas permeability was found to decrease with an increase in gravimetric/ volumetric moisture content and a decrease of suction. The effect of the preconditioning stress was found to be more pronounced at gravimetric moisture contents greater than 40% (25% apparent degree of saturation, 0·30 m3/m3 volumetric moisture content), and suctions less than 1·6 MPa.

Cite

CITATION STYLE

APA

Rouf, M. A., Singh, R. M., Bouazza, A., Rowe, R. K., & Gates, W. P. (2016). Gas permeability of partially hydrated geosynthetic clay liner under two stress conditions. Environmental Geotechnics, 3(5), 325–333. https://doi.org/10.1680/envgeo.14.00009