Peat water in terms of quality cannot be used as a source of clean water or drinking water, so it needs to be processed. One alternative treatment that can be used is the adsorption process with a column system using a chitosan membrane (the content of amine groups contained in the chitosan membrane has a good ability to absorb metals). This study aims to remove Fe metal in peat water. Variations carried out were Fe concentrations of 2, 3 and 4 mg/L and flow rates of 2, 3, 4 and 5 mL/minute. The results obtained are the best Fe metal removal efficiency of 92.20% with a final concentration of 0.312 mg/L at an Fe concentration of 4 mg/L and a flow rate of 2 mL/minute. The results of the study have met the quality standards set by the Minister of Health of the Republic of Indonesia Number 32 of 2017 concerning Sanitary Hygiene
CITATION STYLE
Lubis, K. L., Elystia, S., Ermal, D. A. S., & Zultiniar, Z. (2022). Penyisihan Logam Fe Pada Air Gambut Menggunakan Membran Chitosan Sebagai Adsorben. JURNAL SAINS TEKNOLOGI & LINGKUNGAN, 8(1), 15–24. https://doi.org/10.29303/jstl.v8i1.298