Antibody-magnetite method for selective concentration of Giardia lamblia cysts from water samples

39Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

An antibody-magnetite method was developed in order to selectively concentrate Giardia cysts from water samples. The indirect technique employed a mouse immunoglobulin G anti-Giardia antibody as a primary antibody and an anti-mouse immunoglobulin G antibody-coated magnetite particle as a secondary labeling reagent. The magnetically labeled cysts were then concentrated by high-gradient magnetic separation. Ninety percent of the seeded cysts were recovered from buffer when this method was employed. An average of 82% of the seeded cysts were recovered from water samples with various turbidities. Significantly higher cyst recoveries were obtained from water samples with turbidities below 600 nephelometric turbidity units.

Cite

CITATION STYLE

APA

Bifulco, J. M., & Schaefer, F. W. (1993). Antibody-magnetite method for selective concentration of Giardia lamblia cysts from water samples. Applied and Environmental Microbiology, 59(3), 772–776. https://doi.org/10.1128/aem.59.3.772-776.1993