Objective. Time-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection without phase sorting/binning), is highly desired for regular/irregular motion characterization, patient setup, and motion-adapted radiotherapy. Representing patient anatomy and associated motion fields as 3D Gaussians, we developed a Gaussian representation-based framework (PMF-STGR) for fast and accurate dynamic CBCT reconstruction. Approach. PMF-STGR comprises three major components: a dense set of 3D Gaussians to reconstruct a reference-frame CBCT for the dynamic sequence; another 3D Gaussian set to capture three-level, coarse-to-fine motion-basis-components (MBCs) to model the intra-scan motion; and a CNN-based motion encoder to solve projection-specific temporal coefficients for the MBCs. Scaled by the temporal coefficients, the learned MBCs will be combined into deformation vector fields to deform the reference CBCT into projection-specific, time-resolved CBCTs to capture the dynamic motion. Due to the strong representation power of 3D Gaussians, PMF-STGR can reconstruct dynamic CBCTs in a ‘one-shot’ training fashion from a standard 3D CBCT scan, without using any prior anatomical/motion model. Main results. We evaluated PMF-STGR using XCAT phantom simulations and real patient full/half-fan scans. Metrics, including the image relative error (RE), structural-similarity-index-measure (SSIM), tumor center-of-mass-error (COME), and landmark localization error (LE), were used to evaluate the accuracy of solved dynamic CBCTs and motion. PMF-STGR shows clear advantages over a state-of-the-art, implicit neural representation (INR)-based approach, PMF-STINR. Compared with PMF-STINR, PMF-STGR reduces reconstruction time by ∼50% while reconstructing less blurred images with comparable/better motion accuracy. For XCAT, the mean(±s.d.) RE, SSIM, and COME were 0.128(0.009), 0.990(0.002), and 0.71 mm(0.40 mm) for PMF-STGR, compared with 0.149(0.016), 0.944(0.006), and 0.94 mm(0.18 mm) for PMF-STINR. For patients, the mean(±s.d.) landmark LE was 1.40 mm(0.34 mm) for PMF-STGR, and 1.54 mm(0.35 mm) for PMF-STINR. Significance. With improved efficiency/accuracy, PMF-STGR enhances the applicability of dynamic CBCT imaging for potential clinical translation.

Cite

CITATION STYLE

APA

Xie, J., Shao, H. C., & Zhang, Y. (2025). Time-resolved dynamic CBCT reconstruction using prior-model-free spatiotemporal Gaussian representation (PMF-STGR). Physics in Medicine and Biology, 70(16). https://doi.org/10.1088/1361-6560/adf487

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free