Abstract

This retrospective study presents three consecutive patients who underwent bilateral ureteral occlusion using the Amplatzer vascular plugs and N-butyl cyanoacrylate glue sandwich method. The patients were 63- A nd 65-year-old males and a 79-year-old female. Indications for the procedure included severe cystitis and complex vesicular fistulas unresponsive to urinary diversion. All three patients had immediate resolution of urinary leakage, resulting in symptom relief throughout the follow-up period. There were no procedure-related complications or side effects.

Cite

CITATION STYLE

APA

Jin, M. X., Mohabir, A. D., Caplin, D. M., Lobko, I., & Siegel, D. N. (2018). Transrenal Ureteral Embolization Utilizing Amplatzer Vascular Plugs and N-Butyl Cyanoacrylate Glue. Journal of Endourology Case Reports, 4(1), 108–110. https://doi.org/10.1089/cren.2018.0027