Validation of rapid 4-component body composition assessment with the use of dual-energy X-ray absorptiometry and bioelectrical impedance analysis

51Citations
Citations of this article
94Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background The 4-component (4C) model is a criterion method for human body composition that separates the body into fat, water, mineral, and protein, but requires 4 measurements with significant cost and time requirements that preclude wide clinical use. A simplified model integrating only 2 measurements - dual-energy X-ray absorptiometry (DXA) and bioelectrical impedance analysis (BIA) - and 10 min of patient time has been proposed. Objective We aimed to validate a rapid, simplified 4C DXA + BIA body composition model in a clinical population. Design This was a cross-sectional observational study of 31 healthy adults. Participants underwent whole-body DXA, segmental BIA, air displacement plethysmography (ADP), and total body water (TBW) measurement by deuterium (D 2 O) dilution. 4C composition was calculated through the use of the Lohman model [DXA mineral mass, D 2 O TBW, ADP body volume (BV), scale weight] and the simplified model (DXA mineral mass and BV, BIA TBW, scale weight). Accuracy of percentage of fat (%Fat) and protein measurements was assessed via linear regression. Test-retest precision was calculated with the use of duplicate DXA and BIA measurements. Results Of 31 participants, 23 were included in the analysis. TBW BIA showed good test-retest precision (%CV = 5.2 raw; 1.1 after outlier removal) and high accuracy to TBW D2O [TBW D2O = 0.956∗TBW BIA, R 2 = 0.92, root mean squared error (RMSE) = 2.2 kg]. %Fat estimates from DXA, ADP, D 2 O, and BIA all showed high correlation with the Lohman model. However, only the 4C simplified model provides high accuracy for both %Fat (R 2 = 0.96, RMSE = 2.33) and protein mass (R 2 = 0.76, RMSE = 1.8 kg). %Fat precision from 4C DXA + BIA was comparable with DXA (root mean square-SD = 0.8 and 0.6 percentage units, respectively). Conclusions This work validates a simplified 4C method that measures fat, water, mineral, and protein in a 10-min clinic visit. This model has broad clinical application to monitor many conditions including over/dehydration, malnutrition, obesity, sarcopenia, and cachexia.

Cite

CITATION STYLE

APA

Ng, B. K., Liu, Y. E., Wang, W., Kelly, T. L., Wilson, K. E., Schoeller, D. A., … Shepherd, J. A. (2018). Validation of rapid 4-component body composition assessment with the use of dual-energy X-ray absorptiometry and bioelectrical impedance analysis. American Journal of Clinical Nutrition, 108(4), 708–715. https://doi.org/10.1093/ajcn/nqy158

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free