A high-throughput, nonisotopic, competitive binding assay for kinases using nonselective inhibitor probes (ED-NSIP™)

34Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A novel competitive binding assay for protein kinase inhibitors has been developed for high-throughput screening (HTS). Unlike functional kinase assays, which are based on detection of substrate phosphorylation by the enzyme, this novel method directly measures the binding potency of compounds to the kinase ATP binding site through competition with a conjugated binding probe. The binding interaction is coupled to a signal amplification system based on complementation of β-galactosidase enzyme fragments, a homogeneous, nonisotopic assay technology platform developed by DiscoveRx Corp. In the present study, staurosporine, a potent, nonselective kinase inhibitor, was chemically conjugated to a small fragment of β-galactosidase (termed ED-SS). This was used as the binding probe to the kinase ATP binding pocket. The binding potencies of several inhibitors with diverse structures were assessed by displacement of EDSS from the kinase. The assay format was specifically evaluated with GSK3a, an enzyme previously screened in a radioactive kinase assay (i.e., measurement of [33P]-γ-ATP incorporation into the kinase peptide substrate). Under optimized assay conditions, nonconjugated staurosporine inhibited ED-SS binding in a concentration-dependent manner with an apparent potency (IC50) of 11 nM, which was similar to the IC50 value determined in a radioactive assay. Furthermore, 9 kinase inhibitors with diverse structures, previously identified from chemical compound library screening, were screened using the competitive binding assay. The potencies in the binding assay were in very good agreement with those obtained previously in the isotopic functional activity assay. The binding assay was adapted for automated HTS using selected compound libraries in a 384-well microtiter plate format. The HTS assay was observed to be highly robust and reproducible (Z′ factors > 0.7) with high interassay precision (R2 > 0.96). Interference of compounds with the βgalactosidase signal readout was negligible. In conclusion, the DiscoveRx competitive kinase binding assay, termed EDNSIP™ provides a novel method for screening kinase inhibitors. The format is homogeneous, robust, and amenable to automation. Because there is no requirement for substrate-specific antibodies, the assay is particularly applicable to Ser/ Thr kinase assay, in which difficulties in identifying a suitable substrate and antibody preclude development of nonisotopic assays. Although the nonselective kinase inhibitor, staurosporine, was used here, chemically conjugating the ED fragment to other small molecule enzyme inhibitors is also feasible, suggesting that the format is generally applicable to other enzyme systems. © The Society for Biomolccular Screening.

Cite

CITATION STYLE

APA

Vainshtein, I., Silveria, S., Kaul, P., Rouhani, R., Eglen, R. M., & Wang, J. (2002). A high-throughput, nonisotopic, competitive binding assay for kinases using nonselective inhibitor probes (ED-NSIPTM). Journal of Biomolecular Screening, 7(6), 507–514. https://doi.org/10.1177/1087057102238624

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free