The accuracy of radiology speech recognition reports in a multilingual South African teaching hospital

11Citations
Citations of this article
42Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Speech recognition (SR) technology, the process whereby spoken words are converted to digital text, has been used in radiology reporting since 1981. It was initially anticipated that SR would dominate radiology reporting, with claims of up to 99% accuracy, reduced turnaround times and significant cost savings. However, expectations have not yet been realised. The limited data available suggest SR reports have significantly higher levels of inaccuracy than traditional dictation transcription (DT) reports, as well as incurring greater aggregate costs. Methods: The aim of the study was to compare the accuracy of SR and DT reports in a resource-limited setting. The first 300 SR and the first 300 DT reports generated during March 2010 were retrieved from the hospital's PACS, and reviewed by a single observer. Text errors were identified, and then classified as either clinically significant or insignificant based on their potential impact on patient management. In addition, a follow-up analysis was conducted exactly 4 years later. Results: Of the original 300 SR reports analysed, 25.6% contained errors, with 9.6% being clinically significant. Only 9.3% of the DT reports contained errors, 2.3% having potential clinical impact. Both the overall difference in SR and DT error rates, and the difference in 'clinically significant' error rates (9.6% vs. 2.3%) were statistically significant. In the follow-up study, the overall SR error rate was strikingly similar at 24.3%, 6% being clinically significant. Conclusion: SR technology consistently increased inaccuracies in Tygerberg Hospital (TBH) radiology reports, thereby potentially compromising patient care. Awareness of increased error rates in SR reports, particularly amongst those transcribing in a second-language, is important for effective implementation of SR in a multilingual healthcare environment.

Cite

CITATION STYLE

APA

du Toit, J., Hattingh, R., & Pitcher, R. (2015). The accuracy of radiology speech recognition reports in a multilingual South African teaching hospital. BMC Medical Imaging, 15(1). https://doi.org/10.1186/s12880-015-0048-1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free