A small animal image guided irradiation system study using 3D dosimeters

1Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

In a high resolution image-guided small animal irradiation platform, a cone beam computed tomography (CBCT) is integrated with an irradiation unit for precise targeting. Precise quality assurance is essential for both imaging and irradiation components. The conventional commissioning techniques with films face major challenges due to alignment uncertainty and labour intensive film preparation and scanning. In addition, due to the novel design of this platform the mouse stage rotation for CBCT imaging is perpendicular to the gantry rotation for irradiation. Because these two rotations are associated with different mechanical systems, discrepancy between rotation isocenters exists. In order to deliver x-ray precisely, it is essential to verify coincidence of the imaging and the irradiation isocenters. A 3D PRESAGE dosimeter can provide an excellent tool for checking dosimetry and verifying coincidence of irradiation and imaging coordinates in one system. Dosimetric measurements were performed to obtain beam profiles and percent depth dose (PDD). Isocentricity and coincidence of the mouse stage and gantry rotations were evaluated with starshots acquired using PRESAGE dosimeters. A single PRESAGE dosimeter can provide 3 -D information in both geometric and dosimetric uncertainty, which is crucial for translational studies.

References Powered by Scopus

AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology

649Citations
N/AReaders
Get full text

High-Resolution, Small Animal Radiation Research Platform With X-Ray Tomographic Guidance Capabilities

322Citations
N/AReaders
Get full text

Investigation of radiological properties and water equivalency of PRESAGE® dosimeters

80Citations
N/AReaders
Get full text

Cited by Powered by Scopus

3D isocentricity analysis for clinical linear accelerators

5Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Qian, X., Admovics, J., & Wuu, C. S. (2015). A small animal image guided irradiation system study using 3D dosimeters. In Journal of Physics: Conference Series (Vol. 573). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/573/1/012051

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

80%

Researcher 1

20%

Readers' Discipline

Tooltip

Physics and Astronomy 4

80%

Engineering 1

20%

Save time finding and organizing research with Mendeley

Sign up for free