Objective. This study evaluated whether chest compression in a standardized in-hospital cardiopulmonary resuscitation (CPR) set-up can be performed as effectively as when the rescuer is kneeling beside the patient lying on the floor. Specifically, the in-hospital test was standardized according to the rescuers’ average knee height. Methods. Experimental intervention (test 1) was a standardized, in-hospital CPR set-up: first, the bed height was fixed at 70 cm. Second, the height difference between the bed and a step stool was set to the average knee height of the CPR team members (45 cm). Control intervention (test 2) was kneeling on floor. Thirty-eight medical doctors on the CPR team each performed 2 minutes of chest compressions in test 1 and 2 in random order (cross-over trial). A Little Anne was used as a simulated patient who had experienced cardiac arrest. Chest compression parameters, such as average depth and rate, were measured using an ac-celerometer device. Results. In all tests, the average depths were those recommended in the most recent CPR guidelines (50–60 mm); there were no significant differences between Tests 1 and 2 (53.1 ± 4.3 mm vs. 52.6 ± 4.8 mm, respectively; p = 0.398). The average rate in Test 2 (119.1 ± 12.4 numbers/min) was slightly faster than that in Test 1 (116.4 ± 10.2 numbers/min; p = 0.028). No differences were observed in any other parameters. Conclusions. Chest compression quality in our standardized in-hospital CPR set-up was similar with that performed in a kneeling position on the floor.
CITATION STYLE
Park, T. S., Oh, J. H., Kim, C. W., Lee, D. H., Hong, J. Y., & Kim, S. E. (2017). Development of a standardized in-hospital cardiopulmonary resuscitation set-up. Signa Vitae, 13(2), 49–53. https://doi.org/10.22514/SV132.112017.7
Mendeley helps you to discover research relevant for your work.