MASONRY INFILL PANELS SUBJECTED TO CYCLIC IN-PLANE LOADING.

32Citations
Citations of this article
31Readers
Mendeley users who have this article in their library.

Abstract

A test program of three frames, one unfilled, one filled with reinforced but grouted hollow bricks and one filled with reinforced grouted hollow bricks is reported. The panels, in nominal 4 in. reinforcing bricks, were 3 ft-10 in. high by 5 ft-11 in. long within a reinforced concrete frame of 8 in. by 6 in. section. An in-plane horizontal load was applied to the top of the single-storey single-bay structure. The test results confirm existing analysis methods for stiffness calculation but the strengths of the infill panel frames were not well predicted by these methods. In particular, the behavior of the panels under large static cyclic loading is studied.

Cite

CITATION STYLE

APA

Leuchars, J. M., & Scrivener, J. C. (1976). MASONRY INFILL PANELS SUBJECTED TO CYCLIC IN-PLANE LOADING. NZ Soc Earthquake Eng Bull, 9(2), 122–131. https://doi.org/10.5459/bnzsee.9.2.122-131