Non-Contact Cooperative Manipulation of Magnetic Microparticles Using Two Robotic Electromagnetic Needles

17Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

In this paper, we report a cooperative manipulation method for non-contact robotic electromagnetic needle manipulation system. We employ two 3 degrees of freedom (DOF) robotic electromagnetic needles to achieve an over-actuated manipulator, which can move the particle to any position in the planar workspace from any direction. The redundant DOFs, combined with an optimization-based control approach, enable the manipulator to achieve accurate path following and avoid the collision of needles. Using visual servoing, the developed controller can achieve line following accuracy of 0.33±0.32 μm, square following accuracy of 0.77±0.55 μm, and circle following accuracy of 0.89±0.66 μm with a 4.5 μm diameter superparamagnetic particle. The manipulator can also manipulate a particle along complex paths such as infinity symbol and letter symbols.

Cite

CITATION STYLE

APA

Isitman, O., Bettahar, H., & Zhou, Q. (2022). Non-Contact Cooperative Manipulation of Magnetic Microparticles Using Two Robotic Electromagnetic Needles. IEEE Robotics and Automation Letters, 7(2), 1605–1611. https://doi.org/10.1109/LRA.2021.3137546