Abstract

The article discusses the issues of assessing the technical condition of electric centrifugal pumps (ECP) by the methods of automated diagnostics. The factors influencing the ECP and causes of failures of the electric centrifugal pump (ECP) and the submersible electric motor (SEM) are analyzed. The results of ECP failure identifiaton using the measuring systems are presented. Recommendations on the operation of electric centrifugal pumps are provided.

Cite

CITATION STYLE

APA

Suleimanov, R. I., Khabibullin, M. Y., & Suleimanov, R. I. (2021). Analysis of causes of failure of the electric centrifugal pump elements by the methods of automated diagnostics. In Journal of Physics: Conference Series (Vol. 2061). IOP Publishing Ltd. https://doi.org/10.1088/1742-6596/2061/1/012027