Abstract
A young man working in a workshop sustained penetrating injury to his left eye and reported within 12 hours to Eye Hospital. Plain X-ray orbit confirmed the presence of intraocular foreign body near pars plana. Corneal wound of entry was repaired with 10/0 suture. The intraocular foreign body was removed by magnet through trans scleral magnet via pars plana approach without 3 port vitrectomy procedure. Mild traumatic endophthalmitis was controlled by intravitreal injection of Vancomycin 1mg/0.1ml, along with topical antibiotic and steroid therapy. After 6 weeks, extraction of soft traumatic cataract and posterior chamber lens implantation was done. Best-corrected vision of 6/12 was achieved.
Author supplied keywords
Cite
CITATION STYLE
Qureshi, M. A., Jatoi, S. M., Gul, S., & Laghari, N. A. (2006). Metallic intraocular foreign body removal by magnet v/a trans scleral pars plana approach. Journal of the Liaquat University of Medical and Health Sciences, 5(2), 86–89. https://doi.org/10.22442/jlumhs.06520094