Implementation of an Institution-Wide Rules-Based Automated CT Protocoling System

3Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUND. Examination protocoling is a noninterpretive task that increases radiologists’ workload and can cause workflow inefficiencies. OBJECTIVE. The purpose of this study was to evaluate effects of an automated CT protocoling system on examination process times and protocol error rates. METHODS. This retrospective study included 317,597 CT examinations (mean age, 61.8 ± 18.1 [SD] years; male, 161,125; female, 156,447; unspecified sex, 25) from July 2020 to June 2022. A rules-based automated protocoling system was implemented institution-wide; the system evaluated all CT orders in the EHR and assigned a protocol or directed the order for manual radiologist protocoling. The study period comprised pilot (July 2020 to December 2020), implementation (January 2021 to December 2021), and postimplementation (January 2022 to June 2022) phases. Proportions of automatically protocoled examinations were summarized. Process times were recorded. Protocol error rates were assessed by counts of quality improvement (QI) reports and examination recalls and comparison with retrospectively assigned protocols in 450 randomly selected examinations. RESULTS. Frequency of automatic protocoling was 19,366/70,780 (27.4%), 68,875/163,068 (42.2%), and 54,045/83,749 (64.5%) in pilot, implementation, and postimplementation phases, respectively (p < .001). Mean (± SD) times from order entry to protocol assignment for automatically and manually protocoled examinations for emergency department examinations were 0.2 ± 18.2 and 2.1 ± 69.7 hours, respectively; mean inpatient examination times were 0.5 ± 50.0 and 3.5 ± 105.5 hours; and mean outpatient examination times were 361.7 ± 1165.5 and 1289.9 ± 2050.9 hours (all p < .001). Mean (± SD) times from order entry to examination completion for automatically and manually protocoled examinations for emergency department examinations were 2.6 ± 38.6 and 4.2 ± 73.0 hours, respectively (p < .001); for inpatient examinations were 6.3 ± 74.6 and 8.7 ± 109.3 hours (p = .001); and for outpatient examinations were 1367.2 ± 1795.8 and 1471.8 ± 2118.3 hours (p

Cite

CITATION STYLE

APA

Chung, R., Demers, J. P., Tiberio, R., Savage, C. A., McNulty, F., Stout, M., … Alkasab, T. K. (2024). Implementation of an Institution-Wide Rules-Based Automated CT Protocoling System. American Journal of Roentgenology, 222(4). https://doi.org/10.2214/AJR.23.29806

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free