Functional Performance Outcomes of a Powered Knee–Ankle Prosthesis in Service Members With Unilateral Transfemoral Limb Loss

1Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: Clinical knowledge surrounding functional outcomes of a powered knee–ankle (PKA) device is limited, particularly among younger and active populations with limb loss. Here, three service members (SM) with unilateral transfemoral limb loss received an optimally tuned PKA prosthesis and device-specific training. Materials and Methods: Once proficiency with the PKA device was demonstrated on benchmark activities, and outcomes with the PKA and standard-of-care (SoC) prostheses were obtained via a modified graded treadmill test, 6-minute walk test, and overground gait assessment. Results: All SM demonstrated proficiency with the PKA prosthesis within the minimum three training sessions. With the PKA versus SoC prosthesis, cost of transport during the modified graded treadmill test was 4.0% ± 5.2% lower at slower speeds (i.e., 0.6-1.2 m/s), but 7.0% ± 5.1% greater at the faster walking speeds (i.e., ≥1.4 m/s). For the 6-minute walk test, SM walked 83.9 ± 13.2 m shorter with the PKA versus SoC prosthesis. From the overground gait assessment, SM walked with 20.6% ± 10.5% greater trunk lateral flexion and 31.8% ± 12.8% greater trunk axial rotation ranges of motion, with the PKA versus SoC prosthesis. Conclusions: Compared to prior work with the PKA in a civilian cohort, although SM demonstrated faster device proficiency (3 versus 12 sessions), SM walked with greater compensatory motions compared to their SoC prostheses (contrary to the civilian cohort). As such, it is important to understand patient-specific factors among various populations with limb loss for optimizing device-specific training and setting functional goals for occupational and/or community reintegration, as well as reducing the risk for secondary complications over the long term.

Cite

CITATION STYLE

APA

Knight, A. D., Jayaraman, C., Elrod, J. M., Schnall, B. L., McGuire, M. S., Sleeman, T. J., … Jayaraman, A. (2023). Functional Performance Outcomes of a Powered Knee–Ankle Prosthesis in Service Members With Unilateral Transfemoral Limb Loss. Military Medicine, 188(11–12), 3432–3438. https://doi.org/10.1093/milmed/usac231

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free