Development and Validation of an Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry Method for Quantitation of Total 3,3’,5-triiodo-L-Thyronine and 3,3’,5,5’-tetraiodo-L-Thyronine in Rodent Serum

2Citations
Citations of this article
1Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Many environmental chemicals are known to disrupt thyroid function. Measurement of thyroid hormones in animal studies provides useful information to understand the effects of environmental chemicals on thyroid hormone metabolism. We report an efficient method, utilizing a protein precipitation followed by ultraperformance liquid chromatography-tandem mass spectrometry analysis, to quantitate total 3,3’,5-triiodo-L-thyronine (triiodothyronine, T3) and total 3,3’,5,5’-tetraiodo-L-thyronine (thyroxine, T4) in rodent serum. The use of synthetic serum for calibration standards eliminated the interferences from endogenous total T3 and T4 and allowed the experimental lower limits of quantitation (LOQ) to be set at the required concentration (T3, 20 ng/dL; T4, 0.5 µg/dL) to allow quantitation of endogenous concentrations. The method was linear (r > 0.99; range 20.0-600 ng/dL T3, 0.500-15 µg/dL T4) with good assay recoveries (90.4-107%) for both analytes. Intra- and inter-day accuracy, estimated as percent relative error, were ≤ ±7.6% and intra- and inter-day precision, estimated as the relative standard deviation, were ≤ 5.3% for both analytes. The method may easily be adapted to a well-plate format thereby further improving the efficiency. Total T3 and T4 concentrations were stable in male and female rat and mouse serum when stored in the freezer (∼−70 °C) for up to 62 d with determined values within 92.8-111% of day 0 for both analytes. The method can be extended to quantitate total T3 and T4 concentrations in humans or other species with minimal optimization.

Cite

CITATION STYLE

APA

Waidyanatha, S., Fletcher, B. L., Fernando, R. A., Cora, M. C., & Silinski, M. A. R. (2022). Development and Validation of an Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry Method for Quantitation of Total 3,3’,5-triiodo-L-Thyronine and 3,3’,5,5’-tetraiodo-L-Thyronine in Rodent Serum. Analytical Letters, 55(5), 796–811. https://doi.org/10.1080/00032719.2021.1967969

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free