A study on implementing a phase-shift full-bridge converter employing an asynchronous active clamp circuit

8Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

The conventional Phase-Shift Full-Bridge (PSFB) converter has a serious voltage spike because of the ringing between the leakage inductance of the transformer and the parasitic output capacitance of the secondary side rectifier switches. To overcome this problem, an asynchronous active clamp technique employing an auxiliary DC/DC converter has been proposed. However, an exact analyses for designing the auxiliary DC/DC converter has not been presented. Therefore, the amount of power that is supposed to be handled in the auxiliary DC/DC converter is calculated through a precise mode analyses in this paper. In addition, this paper proposes a lossy snubber circuit with hysteresis characteristics to reduce the burden that the auxiliary DC/DC converter should take during the starting interval. This technique results in optimizing the size of the magnetic component of the auxiliary DC/DC converter. The operational principles and the theoretical analyses are validated through experiments with a 48V-to-30V/15A prototype. © 2014 KIPE.

Cite

CITATION STYLE

APA

Lee, Y. C., Kim, H. K., Kim, J. H., & Hong, S. S. (2014). A study on implementing a phase-shift full-bridge converter employing an asynchronous active clamp circuit. Journal of Power Electronics, 14(3), 413–420. https://doi.org/10.6113/JPE.2014.14.3.413