Venous Obstruction in Asymptomatic Patients Undergoing First Implantation or Revision of a Cardiac Pacemaker or Implantable Cardioverter-Defibrillator: A Retrospective Single Center Analysis

15Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To investigate the incidence and possible risk factors of upper deep vein obstruction in patients both prior to first cardiac device implantation and before device revision. Materials and Methods: Records of asymptomatic patients undergoing contrast venography prior to implantation or revision of a cardiac device from 09/2009 to 04/2012 were reviewed. Venograms were used to determine the presence of venous obstruction. Interrelations between the incidence of venous obstruction and patient- or device-related parameters were identified using Fisher's exact test and univariate logistic regression. Multivariate logistic regression was used to identify independent predictors of venous obstruction. Results: 456 patients met the inclusion criteria (330 males, 126 females, 67.8±12.9 years). 100 patients underwent first implantation, and 356 patients underwent device revision (mean time since implantation 82.5±75.3 months). Venous obstruction was present in 11.0% and 30.1% before implantation and revision, respectively. Only presence of ventricular escape rhythm was significantly related to venous occlusion (p<0.001) prior to first implantation. Prior to revision, significant predictors were male sex (p=0.01), time since implantation (p<0.0001), presence of escape rhythm (p=0.02), compromised coagulation (p=0.02), phenprocoumon (p=0.005), and peripheral arterial disease (p=0.01). Conclusion: Although several risk factors could be identified, reliable prediction of venous obstruction was not possible. Therefore, we advocate performing venography in all patients prior to device revision or upgrade to avoid complications. In cases of first device implantation, the risks associated with venography should be weighed against the surprisingly high rate of deep upper vein obstruction.

Cite

CITATION STYLE

APA

Pieper, C. C., Weis, V., Fimmers, R., Rajab, I., Linhart, M., Schild, H. H., & Nähle, C. P. (2015). Venous Obstruction in Asymptomatic Patients Undergoing First Implantation or Revision of a Cardiac Pacemaker or Implantable Cardioverter-Defibrillator: A Retrospective Single Center Analysis. RoFo Fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren, 187(11), 1029–1035. https://doi.org/10.1055/s-0035-1553351

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free