Surgical smoke is a common chemical hazard produced from the use of electrocautery, laser, or ultrasonic scalpels during surgery. It has been proved harmful to medical personnel. Thus, it is important to monitor surgical smoke concentrations in the operating room. In the past decade, many researches regarding surgical smoke were discussed in different professional healthcare fields, but few showed the correlation between surgical smoke and otolaryngology surgery. In this study, the concentrations of particulate matter and formaldehyde were measured during thirty cases of several types of otolaryngology surgery in a regional research hospital in Taiwan. The concentrations of 0.3 µm and 0.5 µm particulate matter raised rapidly in the main knife range at the beginning of the electrocautery knife used, and then decreased by half after 5–10 min of use. The concentrations of formaldehyde were ranged from 1 to 2 ppm during the surgery, which is higher than the permissible exposure limit. While many medical staffs are working in the operating room and are exposed to the smoke hazard, effective strategies for collecting and eliminating the smoke should be taken in all medical facilities.
CITATION STYLE
Li, C. I., Chou, Y. H., Pai, J. Y., Chen, C. H., & Chiang, M. C. (2022). Investigating surgical smoke in otolaryngology operating rooms. Scientific Reports, 12(1). https://doi.org/10.1038/s41598-022-05701-1