Abstract
Background/Aim: The present study compared the accuracy of visually analyzed (VA) and automatically analyzed (AA) ColonView (CV) quick test; a new-generation fecal immunochemical test (FIT) for hemoglobin (Hb) and hemoglobin/haptoglobin (Hb/Hp) (Biohit Oyj, Helsinki, Finland) in subjects participating in colorectal neoplasia (CRN) detection in Brazil. A traditional guaiac-based fecal occult blood test (gFOBT) test (HemoccultSENSA) was used as a reference. Patients and Methods: A cohort of 509 colonoscopyreferral patients were asked to collect three consecutive fecal samples, to be analyzed by both CV and SENSA. Results: In ROC analysis for the AA reading, the optimal cut-off value for CV Hb was ≥8.0912 and that for CV Hb/Hp was ≥1.8983. With these cut-offs, the sensitivity (Se), specificity (Sp), and efficiency of CV AA in detecting colorectal adenoma (CRA) were: 64.2%/78.6%, 53.4%/35.3%, and 58.6%/56.5%, for Hb and Hb/Hp, respectively. In the HSROC analysis, the AUC values for i) VA and ii) AA modes were as follows: I) AUC=0.551 (95%CI=0.500-0.602), ii) AUC=0.606 (95%CI=0.550-0.662).
Author supplied keywords
Cite
CITATION STYLE
MEKLIN, J., ESKELINEN, M., GUIMARAES, D. P., SELANDER, T., TIUSANEN, T., SYRJÄaNEN, K., & ESKELINEN, M. (2021). The automatically analyzed (aa) colonview (cv) quick test for fecal occult blood shows higher diagnostic accuracy in detection of colorectal adenoma than visually analyzed tests. Anticancer Research, 41(11), 5517–5525. https://doi.org/10.21873/anticanres.15365