Serial Multimodality Imaging and 2-Year Clinical Outcomes of the Novel DESolve Novolimus-Eluting Bioresorbable Coronary Scaffold System for the Treatment of Single De Novo Coronary Lesions

107Citations
Citations of this article
86Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives This study sought to report the late multimodality imaging and clinical outcomes of the novel poly-l-lactic-acid-based DESolve novolimus-eluting bioresorbable coronary scaffold for the treatment of de novo coronary lesions. Background Bioresorbable scaffolds are an alternative to drug-eluting metallic stents and provide temporary vascular scaffolding, which potentially may allow vessel restoration and reduce the risk of future adverse events. Methods Overall, 126 patients were enrolled at 13 international sites between November 2011 and June 2012. The primary endpoint was in-scaffold late lumen loss at 6 months. Major adverse cardiac events, the main safety endpoint, were defined as the composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. All patients underwent angiography at 6 months. Serial intravascular ultrasound and optical coherence tomography were performed in a subset of patients. Results The scaffold device success rate was 97% (n = 122 of 126), and procedural success was 100% (n = 122 of 122). The major adverse cardiac event rate was 3.3% (n = 4 of 122) at 6 months and 7.4% (n = 9 of 122) at 24 months, including 1 probable stent thrombosis within the first month. At 6-month angiographic follow-up, in-scaffold late lumen loss was 0.20 ± 0.32 mm. Paired intravascular ultrasound analysis demonstrated a significant increase in vessel, lumen and scaffold dimensions between post-procedure and 6-month follow-up, and strut-level optical coherence tomography analysis showed full strut coverage in 99 ± 1.7%. Conclusions Our results showed favorable performance of the DESolve scaffold, effective inhibition of neointimal hyperplasia, and for the first time, early luminal and scaffold growth at 6 months with sustained efficacy and safety through 2 years. (Elixir Medical Clinical Evaluation of the DESolve Novolimus Eluting Bioresorbable Coronary Scaffold System - The DESolve Nx Trial; NCT02086045).

Cite

CITATION STYLE

APA

Abizaid, A., Costa, R. A., Schofer, J., Ormiston, J., Maeng, M., Witzenbichler, B., … Verheye, S. (2016). Serial Multimodality Imaging and 2-Year Clinical Outcomes of the Novel DESolve Novolimus-Eluting Bioresorbable Coronary Scaffold System for the Treatment of Single De Novo Coronary Lesions. JACC: Cardiovascular Interventions, 9(6), 565–574. https://doi.org/10.1016/j.jcin.2015.12.004

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free